Low Frequency Transformers up to 400 Hz
Custom Avionics, Aerospace & Medical Power Transformers

Electronetics offers a wide variety of line frequency power transformers for 50 Hz, 60 Hz and 400 Hz applications for the avionics, aerospace and medical industries, to name a few. Electronics also offered sensing transformers (current or voltage) that deliver extremely accurate output while maintaining high isolation, small size and low cost. Our capabilities include:
Line - Line Isolation Transformer
This transformer is typically either 60 Hz or 50 Hz running from a wall socket or from commercial AC. Isolation is commonly listed as a voltage rating for shock safety.
Line - Line Autotransformer
Very similar to the line - line isolation transformer but without electrical isolation between the primary and secondary. Frequently used to slightly step-up or step-down voltage to allow for use of smaller core and coil (e.g. stepping up from 208 Volts to 240 Volts or stepping down from 240 Volts to 220 Volts).
Audio Isolation Transformer
These transformers are often used to distribute an audio amplifier's output to multiple speakers.
Current Sensing Transformer
These transformers sample high current through the primary and deliver an exact replica to the secondary at a lower current. May be high or low frequency, but are frequently in the 50 Hz to 400 Hz range. Minimum isolation voltage is often required between primary and secondary.
Voltage Sensing Transformer
Like current sensing transformers, voltage sensing transformers sample high voltage through the primary and deliver an exact replica to the secondary at a lower voltage. They are most often used for line frequency applications at 50 Hz and 60 Hz, but the range can be as wide as that of the current sensing transformer. Minimum isolation voltage is often required between primary and secondary.
Line - Line Isolation Transformer
This transformer is typically either 60 Hz or 50 Hz running from a wall socket or from commercial AC. Isolation is commonly listed as a voltage rating for shock safety.
Line - Line Autotransformer
Very similar to the line - line isolation transformer but without electrical isolation between the primary and secondary. Frequently used to slightly step-up or step-down voltage to allow for use of smaller core and coil (e.g. stepping up from 208 Volts to 240 Volts or stepping down from 240 Volts to 220 Volts).
Audio Isolation Transformer
These transformers are often used to distribute an audio amplifier's output to multiple speakers.
Current Sensing Transformer
These transformers sample high current through the primary and deliver an exact replica to the secondary at a lower current. May be high or low frequency, but are frequently in the 50 Hz to 400 Hz range. Minimum isolation voltage is often required between primary and secondary.
Voltage Sensing Transformer
Like current sensing transformers, voltage sensing transformers sample high voltage through the primary and deliver an exact replica to the secondary at a lower voltage. They are most often used for line frequency applications at 50 Hz and 60 Hz, but the range can be as wide as that of the current sensing transformer. Minimum isolation voltage is often required between primary and secondary.
Transformer Types:
Audio Isolation Transformer Current-sensing Transformer Line-Line Autotransformer Line-Line Isolation Transformer Voltage-sensing Transformer Construction: Laminated Toroidal Primary Voltage Range: 10-500 VAC Single Phase 10-580 VAC 3-Phase, etc. Operating Frequency: From line frequencies (50/60/400 Hz) Secondary Voltage Range Up to 5,000V Output Power Rating: Up to 100 kVA Mounting: Free Standing Coil Horizontal Chassis Mounting PCB Mounting Vertical Chassis Mounting Termination: Flying Leads PCB Pins (Thru-Hole Bobbin Terminal) Quick Disconnect Terminals Solder Lugs PCB Surface Mount Terminations (SMT) |
Effective Design Options:
Cooling Systems Custom Footprint Design Encapsulation Low Profile Design Magnetic Shielding Applications: Audio Amplifier Power Supplies, Aerospace, Medical, Avionics, Commercial Products Residential Scientific & Laboratory Equipment Order Quantity: No order is too small or too large Typical Lead-Time: Lead-time depends on customer requirements and material lead-times Quality Assurance: 100% HiPot Testing 100% Parametric Acceptance Testing 100% Visual Inspection Continuous Process Improvement In-process inspections ISO 9001 : 2015 Certified Test Results are captured and available as part of the documentation UL 5506 Flammability Standard construction materials UL Listed Insulation Systems 130°C, 155°C, 180°C, 200°C, 220°C. |